Mucopolysaccharides, Quantitative, Urine
Also known as: MPS QNT
Use
This test is used to monitor glycosaminoglycans (GAGs) in patients who have been previously diagnosed with a mucopolysaccharidosis (MPS). Monitoring GAG levels is crucial for managing patients with MPS as it helps in assessing disease progression and treatment efficacy.
Special Instructions
A morning urine void is preferred for specimen collection. Ensure the immediate transfer of urine to ARUP Standard Transport Tubes for freezing, as stability is affected by temperature.
Limitations
The test is not suitable for initial screening for MPS. It is specifically designed for monitoring purposes in patients already diagnosed with mucopolysaccharidosis. Specimens contaminated or containing preservatives are unacceptable, potentially affecting the accuracy of the results.
Methodology
Automated Analyzer
Biomarkers
LOINC Codes
- 46132-7
Result Turnaround Time
3-9 days
Related Documents
For more information, please review the documents below
Specimen
Urine
Volume
10 mL
Minimum Volume
5 mL
Container
ARUP Standard Transport Tubes
Collection Instructions
Collect urine with a preference for morning void. Transfer immediately to transport tubes and freeze.
Storage Instructions
Store specimens frozen. Avoid repeated freeze/thaw cycles.
Causes for Rejection
Contaminated specimens or specimens containing preservatives.
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | Unacceptable |
| Refrigerated | Unacceptable |
| Frozen | 1 month |