Phospholipids, Serum or Plasma
Use
This test is useful in the evaluation of liver disease, particularly obstructive jaundice. The measurement of phospholipids can provide important information regarding liver function and possible cholestasis.
Special Instructions
Patient should fast for 12 hours prior to collection to ensure accurate results. Specimens should be collected in a serum separator tube, plain red, lavender (EDTA), pink (K2EDTA), or green (sodium or lithium heparin) tube.
Limitations
The performance characteristics were determined by ARUP Laboratories, and the test was developed as a Laboratory Developed Test (LDT). It has not been cleared or approved by the US Food and Drug Administration, which may limit its acceptance in certain regulatory environments. Results may be affected by improper specimen collection, handling, or storage, which could lead to inaccurate measurements.
Methodology
Automated Analyzer (Clinical Chemistry)
Biomarkers
LOINC Codes
- 2568-4
Result Turnaround Time
1-4 days
Related Documents
For more information, please review the documents below
Specimen
Serum
Volume
1 mL
Minimum Volume
0.5 mL
Container
ARUP standard transport tube
Collection Instructions
Allow the specimen to clot completely at room temperature before transfer.
Patient Preparation
Patient should fast for 12 hours prior to collection.
Storage Instructions
Refrigerated
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | 8 hours |
| Refrigerated | 1 month |
| Frozen | 1 month |