ToxAssure® Flex 16, Urine
Use
This test is used to detect the presence of prescribed, over-the-counter and illicit drugs for the purpose of medical drug monitoring.
Special Instructions
Not provided.
Limitations
The analysis might not detect substances that were only present in concentrations below the detection thresholds. The results should be interpreted within the context of a comprehensive clinical assessment, including a reliable patient history, other laboratory findings, and clinical observations. Cross-reactivity with non-target compounds might produce false positives or negatives, requiring confirmatory testing when results are critical to treatment decisions.
Methodology
Mass Spectrometry
Biomarkers
LOINC Codes
- 87428-9 - Drugs of abuse W Reflex Pnl Ur
- 66149-6 - Prescribed medications
- 11502-2 - Laboratory report
- 2161-8 - Creat Ur-mCnc
- 19261-7 - Amphetamines Ur Ql Scn
- 19285-6 - Benzodiaz Scn Meth Ur
- 64130-8 - diazePAM/Creat Ur
- 58367-4 - Nordiazepam/Creat Ur
- 58368-2 - Oxazepam/Creat Ur
- 58369-0 - Temazepam/Creat Ur
- 86224-3 - Alpraz/Creat Ur Cfm
- 58363-3 - A-OH Alpraz/Creat Ur
- 64129-0 - Desalkylfluraz/Creat Ur
- 58366-6 - LORazepam/Creat Ur
- 86605-3 - A-OH-triazolam/Creat Ur Cfm
- 86225-0 - clonazePAM/Creat Ur Cfm
- 58364-1 - 7Aminoclonazepam/Creat Ur
- 86231-8 - Midazolam/Creat Ur Cfm
- 94108-8 - 1OH-midazolam Ur Ql Scn
- 19466-2 - Flunitrazepam Ur Ql Scn
- 27083-5 - Norflunitrazepam Ur-mCnc
- 42241-0 - Cocaine+BZE Ur Ql Scn
- 42242-8 - Ethanol Ur Ql Scn
- 18282-4 - Cannabinoids Ur Ql Scn
- 19321-9 - 6MAM Ur Ql Scn
- 70150-8 - Opiates Ur Scn-mCnc
- 19644-4 - oxyCODONE CtO Ur Scn-mCnc
- 19550-3 - Methadone Ur Ql Scn
- 42251-9 - Methadone+metab Ur Ql Scn
- 93494-3 - Buprenorphine Ur Ql Scn
- 58360-9 - Buprenorphine/Creat Ur
- 58361-7 - Norbuprenorphine/Creat Ur
- 79260-6 - fentaNYL CtO Ur Scn-mCnc
- 58380-7 - fentaNYL/Creat Ur
- 58382-3 - Norfentanyl/Creat Ur
- 79240-8 - Tapentadol CtO Ur Scn-mCnc
- 19710-3 - traMADol Ur Ql Scn
- 19577-6 - Me-phenidate Ur Ql Scn
- 19270-8 - Barbiturates Ur Ql Scn
- 19659-2 - PCP Ur Ql Scn
Result Turnaround Time
5-7 days
Related Documents
For more information, please review the documents below
Specimen
Urine
Volume
10 mL
Minimum Volume
3 mL
Container
Plastic urine container without preservative
Storage Instructions
Submission/transport (<3 days): Room temperature. For storage beyond three days, specimen should be refrigerated or frozen.
Causes for Rejection
Urine from preservative tube
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 6 weeks |