Erythroid‑Mega Add‑On Flow Panel
Also known as: Erythroid-Megakaryocyte Add-On Flow Panel
Use
This add‑on flow cytometry panel is designed to clarify findings in samples currently undergoing flow cytometric analysis at NeoGenomics. It targets erythroid and related markers to refine immunophenotypic assessment and aid diagnostic decision‑making when combined with standard leukemia/lymphoma flow panels.
Special Instructions
Available either as Global service or Tech‑Only (stand‑alone) service. It must be run in conjunction with Standard or Extended Leukemia/Lymphoma flow cytometry panels unless ordered as Tech‑Only. New York State approval status: Yes.
Limitations
Stand‑alone testing is only available for the Tech‑Only version; for Global use, this panel must accompany full flow cytometry panels. The panel adds eight markers and does not function as a comprehensive stand‑alone immunophenotyping test.
Methodology
Cell-based / Cytometry (Flow Cytometry)
Biomarkers
Result Turnaround Time
24 hours
Related Documents
For more information, please review the documents below
Specimen
Bone Marrow
Volume
Not provided
Minimum Volume
Not provided
Storage Instructions
Refrigerate specimen, do not freeze. Use cold pack for transport, ensuring it does not make direct contact with specimen.
Stability Requirements
| Temperature | Period |
|---|---|
| Refrigerated | Receive within 72 hours of collection (48 hours for NYS samples). |