Cardio IQ® Myeloperoxidase (MPO)
Also known as: CardioIQ®
Use
Myeloperoxidase testing may be used for individuals with multiple risk factors for cardiovascular disease, or those with established disease.
Special Instructions
Not provided.
Limitations
Not provided.
Methodology
Immunoassay (Turbidimetric Immunoassay)
Biomarkers
Result Turnaround Time
Not provided.
Related Documents
For more information, please review the documents below
Specimen
Plasma
Volume
Not provided
Minimum Volume
0.5 mL
Container
EDTA (lavender‑top) tube
Collection Instructions
Draw and gently invert 8 to 10 times; centrifuge immediately for 10 minutes at 1300 RCF at room temperature; pre‑squeeze transfer pipet bulb and draw off approximately 2/3 of the upper plasma layer; aliquot plasma into labeled transport tube labeled as “EDTA plasma and cap tightly. Discard original tube.
Storage Instructions
Store transport tube refrigerated at 2‑8 °C until ready to ship. Store plasma at 2‑8 °C after collection and ship same day.
Causes for Rejection
Gross hemolysis; samples other than EDTA plasma including PPT potassium EDTA (white‑top) tube; improper labeling; samples not stored properly; samples older than stability limits
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | Unacceptable |
| Refrigerated | 8 days |
| Frozen | 6 months |