Motor Neuropathy Panel
Also known as: MSN PAN
Use
The Motor Neuropathy Panel aids in the diagnosis of motor neuropathy, especially in cases where plasma cell dyscrasia is suspected. It includes the measurement of various globulins, immunoglobulins, and antibodies that are pertinent in understanding neuropathic conditions. Elevated levels of certain antibodies might suggest active demyelination and peripheral neuropathies. This test is valuable in differentiating between various neuropathic conditions.
Special Instructions
Not provided.
Limitations
Plasma, CSF, or body fluids other than serum are unacceptable. Room temperature, contaminated, heat-inactivated, hemolyzed, severely icteric, or lipemic specimens are also unacceptable. The antibody tests are not diagnostic on their own and should be used in conjunction with clinical data to confirm disease. Interpretive caution is advised due to possible reactivity against more than one epitope or protein.
Methodology
Immunoassay (ELISA)
Biomarkers
LOINC Codes
- 2862-1 - Albumin SerPl Elph-mCnc
- 2865-4 - Alpha1 Glob SerPl Elph-mCnc
- 2868-8 - Alpha2 Glob SerPl Elph-mCnc
- 2871-2 - B-Globulin SerPl Elph-mCnc
- 2874-6 - Gamma glob SerPl Elph-mCnc
- 25700-6 - Interpretation SerPl IFE-Imp
- 2458-8 - IgA SerPl-mCnc
- 2465-3 - IgG SerPl-mCnc
- 2472-9 - IgM SerPl-mCnc
- 2885-2 - Prot SerPl-mCnc
- 88723-2 - GM1 Asialo IgG+IgM Ser IA-aCnc
- 31500-2 - GM1 Gangl IgG+IgM Ser-aCnc
- 88724-0 - GD1a Gangl IgG+IgM Ser IA-aCnc
- 88730-7 - GD1b Gangl IgG+IgM Ser IA-aCnc
- 88729-9 - GQ1b Gangl IgG+IgM Ser IA-aCnc
- 31666-1 - SGPG IgM Ser-aCnc
- 17314-6 - MAG IgM Ser IA-aCnc
- 49275-1 - Interpretation SerPl IFE-Imp
- 33358-3 - M Protein SerPl Elph-mCnc
- 11526-1 - Pathology study
Result Turnaround Time
1-8 days
Related Documents
For more information, please review the documents below
Specimen
Serum
Volume
4 mL
Minimum Volume
2 mL
Container
ARUP standard transport tube
Collection Instructions
Separate from cells ASAP or within 2 hours of collection. Transfer 4 mL serum to an ARUP standard transport tube. (Min: 2 mL)
Storage Instructions
Refrigerated.
Causes for Rejection
Plasma, CSF, or other body fluids. Room temperature specimens. Contaminated, heat-inactivated, hemolyzed, severely icteric, or lipemic specimens.
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | Unacceptable |
| Refrigerated | 1 week |
| Frozen | 1 month |
Other tests from different labs that may be relevant