Estradiol
Use
This estradiol assay is designed for the investigation of fertility of women of reproductive age and for the support of in vitro fertilization.
Special Instructions
Not provided.
Limitations
In children, postmenopausal women, and men, E2 levels are significantly lower than in reproductive-age women, warranting LC/MS-MS for greater sensitivity and specificity. Methods like ECLIA may not provide accurate measurements for these groups. Results from different assay techniques are not interchangeable. Interference from monoclonal mouse antibodies and certain drugs like fulvestrant may result in inaccurate results; consider sensitive methods like LC/MS-MS for these cases.
Methodology
Immunoassay (ECLIA)
Biomarkers
Estradiol
Analyte
LOINC Codes
- 2243-4 - Estradiol SerPl-mCnc
- 2243-4 - Estradiol SerPl-mCnc
Result Turnaround Time
1 day
Related Documents
For more information, please review the documents below
Specimen
Serum
Volume
1 mL
Minimum Volume
0.7 mL
Container
Red-top tube, gel-barrier tube
Collection Instructions
If a red-top tube or plasma is used, transfer separated serum or plasma to a plastic transport tube.
Storage Instructions
Room temperature
Causes for Rejection
Citrate plasma specimen; improper labeling
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
Other tests from different labs that may be relevant