Donor, Hepatitis C Antibody (Anti‑HCV)
Use
This test is intended to be used as a primary screening test for the diagnosis of acute or chronic hepatitis due to Hepatitis C virus (HCV) infection. It is approved by the FDA for screening of donors of blood, blood components and human cells, tissues and tissue‑based products (HCT&P), and is also intended for use to screen organ donors (both heart‑beating and cadaveric). A positive result is indicative of infection with HCV and may be used to disqualify a potential donor. It is not intended for routine clinical diagnostic testing and not for use on cord blood specimens.
Special Instructions
Not provided.
Limitations
Not intended for routine clinical diagnostic testing. Not for use on cord blood specimens.
Methodology
Immunoassay (Other)
Biomarkers
Hepatitis C virus antibody
Protein
Result Turnaround Time
36 hours
Related Documents
For more information, please review the documents below
Specimen
Serum
Volume
2 mL
Minimum Volume
1 mL
Collection Instructions
Serum, or Plasma collected in an EDTA (lavender‑top) tube.
Causes for Rejection
Gross hemolysis; Sample not marked serum/plasma; Specimens other than serum or plasma; Heat‑inactivated specimens; Pooled specimens; Specimens with obvious microbial contamination; Specimens with fungal growth
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | 7 days |
| Refrigerated | 14 days |
| Frozen | 9 months |