Androstanediol Glucuronide (Endocrine Sciences)
Use
Quantitative measurement of androstanediol glucuronide in serum or plasma, useful in the clinical evaluation of androgen excess, such as hirsutism in females or androgen-related disorders in males. The measurement informs endocrine assessment and management.
Special Instructions
Not provided.
Limitations
Specimen separation from cells must occur within 45 minutes of venipuncture; minimum specimen volume (0.5 mL) does not allow for repeat testing. Additional time may be required for confirmatory or reflex testing.
Methodology
Mass Spectrometry
Biomarkers
LOINC Codes
- 1680-8
- 1680-8
Result Turnaround Time
8-15 days
Related Documents
For more information, please review the documents below
Specimen
Serum
Volume
1 mL
Minimum Volume
0.5 mL
Container
Red‑top tube or gel‑barrier tube or lavender‑top (EDTA) tube
Collection Instructions
Serum or plasma must be separated from cells within 45 minutes of venipuncture. Submit specimen in a plastic transport tube.
Storage Instructions
Refrigerated (preferred) or room temperature.
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | 6 days |
| Refrigerated | 6 days |
| Frozen | 3 years |