Euroglyphus maynei
Use
The Euroglyphus maynei test is used for measuring specific Immunoglobulin E (IgE) antibodies to identify allergic reactions to the house dust mite, Euroglyphus maynei. This test can help determine if a patient has developed hypersensitivity to this allergen and assist healthcare providers in diagnosing allergic conditions, making treatment decisions, and recommending preventive measures.
Special Instructions
This test requires a serum specimen and involves the use of the Thermo Fisher ImmunoCAP® technology for detecting specific IgE antibodies. Patients may need to follow specific collection and storage instructions to ensure the integrity of the serum sample.
Limitations
The test is limited to the assessment of IgE-mediated allergy reactions specific to Euroglyphus maynei and does not account for other possible allergens. False negatives can occur if IgE levels are below the detection threshold. Cross-reactivity with other allergens similar to house dust mite may also impact results.
Methodology
Immunoassay (Thermo Fisher ImmunoCAP®)
Biomarkers
LOINC Codes
- 6114-3
- 6114-3
Result Turnaround Time
3-5 days
Related Documents
For more information, please review the documents below
Specimen
Serum
Volume
1 mL
Minimum Volume
Not provided
Container
One 8.5-mL red-top tube or one 8.5-mL gel-barrier tube
Storage Instructions
Room temperature
Stability Requirements
| Temperature | Period |
|---|---|
| Room Temperature | 14 days |
| Refrigerated | 14 days |